Came magnetic induction loop detector, 2-channel, 24 V
- Came 2-channel induction loop detector for two loops in the road surface
- Power supply 24 V AC/DC, 2 output relays, LCD display, DIN rail mounting
- The copper wire loops and laying them in the road surface must be arranged separately
Call us, we will help you choose the right part or accessory.
Description
The Came SMA2 (009SMA2) evaluates two induction loops laid in the road surface. When a metal vehicle stands on or passes over a loop, the detector switches the output relay and sends a signal to the control unit. Use it with barriers, industrial doors and in car parks.
Functions
- Modes – gate, barrier, closed-circuit or direction logic: output 1 switches when passing from loop 1 to loop 2, output 2 the other way round.
- Outputs – 2 relays (max. 240 V AC / 2 A or 30 V DC / 1 A) and an optional fault output.
- Settings – time functions, 9 sensitivity levels, ASB function for trailer drawbars and 4 frequencies so that detectors do not interfere with each other.
Things to bear in mind before installation
- Location – 35 mm DIN rail in a distribution board or enclosure, protection rating IP20.
- Loop – inductance 20–1000 µH, ideally 80–300 µH, loop resistance including feeder below 8 Ω. The site preparation diagram is in the attachment.
- Feeder – twist the wires at least 20 times per metre. With a cross-section of 1.5 mm², max. 100 m (20–40 µH) or 200 m (over 40 µH).
For a mains power supply there is the 230 V version; for one loop, the Came SMA is enough. An alternative is the Nice LP22. Send any questions to eshop@saver.sk; for wiring in the Košice and Prešov regions, see the service section.
Specifications
| Number of channels | 2-channel |
| Power supply | 24 V AC/DC |
| Dimensions | 22,5 × 94 × 88 mm |
| Weight | 300 g |
| Protection rating | IP20 |
| Max. power consumption | 1,5 W |
| Operating temperature | -20 až +60 °C |