Came magnetic induction loop detector, 2-channel, 230 V
- Came 2-channel induction loop detector with mains power supply
- Power supply 100–240 V AC, 2 output relays, LCD display, DIN rail mounting
- The copper wire loops and laying them in the road surface must be arranged separately
Call us, we will help you choose the right part or accessory.
Description
The Came SMA220 (009SMA230) is a version of the 2-channel loop detector that you power directly from the 100–240 V AC mains. It is suitable where you do not have a 24 V supply in the distribution board. The detector evaluates two induction loops in the road surface and switches the output relay when a metal vehicle is present.
Functions
- Modes – gate, barrier, closed-circuit or direction logic according to the order in which the vehicle passes over the loops.
- Outputs – 2 relays (max. 240 V AC / 2 A or 30 V DC / 1 A) and an optional fault output.
- Settings – with the Mode and Data buttons: time functions, 9 sensitivity levels, ASB function and 4 frequencies.
Things to bear in mind before installation
- Power supply – 100–240 V AC, 50/60 Hz, power consumption max. 2.9 VA. Only connect it with the power off.
- Location – 35 mm DIN rail in a distribution board, protection rating IP20.
- Loop and feeder – inductance ideally 80–300 µH, resistance including feeder below 8 Ω, feeder twisted at least 20 times per metre. The site preparation diagram is in the attachment.
The 24 V AC/DC version is the Came SMA2; for one loop, the Came SMA. You will find barriers in the road barriers category. Send any questions to eshop@saver.sk; for wiring in the Košice and Prešov regions, see the service section.
Specifications
| Number of channels | 2-channel |
| Power supply | 100–240 V AC, 50/60 Hz |
| Dimensions | 22,5 × 94 × 88 mm |
| Weight | 300 g |
| Protection rating | IP20 |
| Max. power consumption | 2,9 VA |
| Operating temperature | -20 až +60 °C |